What is RAID
|
RAID Fundamentals |
|
The basic idea of
RAID (Redundant Array of Independent
Disks) is to combine multiple inexpensive disk drives into an array
of disk drives to obtain performance, capacity and reliability that
exceeds that of a single large drive. The array of drives appears to
the host computer as a single logical drive.The Mean Time Between Failure
(MTBF) of the array is equal to the
MTBF of an individual drive, divided by the number of drives in the
array. Because of this, the MTBF of a non-redundant array (RAID
0)
is too low for mission-critical systems. However, disk arrays can be
made fault-tolerant by redundantly storing information in various
ways.
Five types of array architectures,
RAID 1 through RAID
5, were
originally defined, each provides disk fault-tolerance with
different compromises in features and performance. In addition to
these five redundant array architectures, it has become popular to
refer to a non-redundant array of disk drives as a RAID 0 array. |
|
|
|
Disk Striping
|
|
Fundamental
to RAID technology is striping. This is a method of combining
multiple drives into one logical storage unit. Striping partitions
the storage space of each drive into stripes, which can be as small
as one sector (512 bytes) or as large as several megabytes. These
stripes are then interleaved in a rotating sequence, so that the
combined space is composed alternately of stripes from each drive.
The specific type of operating environment determines whether large
or small stripes should be used.
Most
operating systems today support concurrent disk I/O operations
across multiple drives. However, in order to maximize throughput for
the disk subsystem, the I/O load must be balanced across all the
drives so that each drive can be kept busy as much as possible. In a
multiple drive system without striping, the disk I/O load is never
perfectly balanced. Some drives will contain data files that are
frequently accessed and some drives will rarely be accessed.
By striping the drives in the array with stripes large enough so
that each record falls entirely within one stripe, most records can
be evenly distributed across all drives. This keeps all drives in
the array busy during heavy load situations. This situation allows
all drives to work concurrently on different I/O operations, and
thus maximize the number of simultaneous I/O operations that can be
performed by the array. |
| |
| Definition of RAID
Levels |
RAID 0 is typically defined as a
group of striped disk drives without parity or data redundancy. RAID
0 arrays can be configured with large stripes for multi-user
environments or small stripes for single-user systems that access
long sequential records. RAID 0 arrays deliver the best data storage
efficiency and performance of any array type. The disadvantage is
that if one drive in a RAID 0 array fails, the entire array fails. |
|
RAID 1, also known as disk mirroring, is simply a pair of
disk drives that store duplicate data but appear to the computer as
a single drive. Although striping is not used within a single
mirrored drive pair, multiple RAID 1 arrays can be striped together
to create a single large array consisting of pairs of mirrored
drives. All writes must go to both drives of a mirrored pair so that
the information on the drives is kept identical. However, each
individual drive can perform simultaneous, independent read
operations. Mirroring thus doubles the read performance of a single
non-mirrored drive and while the write performance is unchanged.
RAID 1 delivers the best performance of any redundant array type. In
addition, there is less performance degradation during drive failure
than in RAID 5 arrays. |
|
RAID 2 arrays sector-stripe data across groups of drives,
with some drives assigned to store ECC information. Because all disk
drives today embed ECC information within each sector, RAID 2 offers
no significant advantages over other RAID architectures and is not
supported by Adaptec RAID controllers. |
|
RAID 3, as with
RAID 2, sector-stripes data across groups
of drives, but one drive in the group is dedicated to storing parity
information. RAID 3 relies on the embedded ECC in each sector for
error detection. In the case of drive failure, data recovery is
accomplished by calculating the exclusive OR (XOR) of the
information recorded on the remaining drives. Records typically span
all drives, which optimizes the disk transfer rate. Because each I/O
request accesses every drive in the array, RAID 3 arrays can satisfy
only one I/O request at a time. RAID 3 delivers the best performance
for single-user, single-tasking environments with long records.
Synchronized-spindle drives are required for RAID 3 arrays in order
to avoid performance degradation with short records. Because RAID 5
arrays with small stripes can yield similar performance to RAID 3
arrays, RAID 3 is not supported by Adaptec
RAID controllers. |
|
RAID 4 is identical to
RAID 3 except that large stripes
are used, so that records can be read from any individual drive in
the array (except the parity drive). This allows read operations to
be overlapped. However, since all write operations must update the
parity drive, they cannot be overlapped. This architecture offers no
significant advantages over other RAID levels and is not supported
by Adaptec RAID controllers. |
|
RAID
5, sometimes called a
Rotating Parity Array, avoids the write bottleneck caused by
the single dedicated parity drive of RAID
4. Under RAID 5 parity
information is distributed across all the drives. Since there
is no dedicated parity drive, all drives contain data and read
operations can be overlapped on every drive in the array.
Write operations will typically access one data drive and one
parity drive. However, because different records store their
parity on different drives, write operations can usually be
overlapped. |
|
In summary:
RAID 0 is the fastest and most efficient array type but offers
no fault-tolerance. RAID 0 requires a minimum of two drives.
RAID 1 is the best choice for performance-critical,
fault-tolerant environments. RAID 1 is the only choice for
fault-tolerance if no more than two drives are used.
RAID 2 is seldom used today since ECC is embedded in all hard
drives. RAID 2 is not supported by Adaptec
RAID controllers.
RAID 3 can be used to speed up data transfer and provide
fault-tolerance in single-user environments that access long
sequential records. However, RAID 3 does not allow overlapping
of multiple I/O operations and requires synchronized-spindle
drives to avoid performance degradation with short records.
Because RAID 5 with a small stripe size offers similar
performance, RAID 3 is not supported by Adaptec
RAID
controllers.
RAID 4 offers no advantages over
RAID 5 and does not support
multiple simultaneous write operations. RAID 4 is not supported
by Adaptec RAID controllers.
RAID 5 combines efficient, fault-tolerant data storage with
good performance characteristics. However, write performance and
performance during drive failure is slower than with RAID
1.
Rebuild operations also require more time than with RAID 1
because parity information is also reconstructed. At least three
drives are required for RAID 5 arrays.
|
|
|
|
Dual-Level RAID
|
|
In addition to the standard
RAID levels,
Adaptec RAID controllers can combine multiple hardware
RAID arrays
into a single array group or parity group. In a dual-level RAID
configuration, the controller firmware stripes two or more hardware
arrays into a single array.
NOTE
The arrays being combined must both use the same
RAID level.
Dual-level
RAID achieves a balance between the increased data
availability inherent in RAID 1 and RAID 5 and the increased read
performance inherent in disk striping (RAID 0). These arrays are
sometimes referred to as RAID 0+1 or RAID 10 and
RAID 0+5 or RAID
50. |
|
|
|
Creating Data Redundancy
|
|
RAID 5 offers improved storage efficiency
over RAID 1 because only the parity information is stored, rather
than a complete redundant copy of all data. The result is that three
or more drives can be combined into a RAID 5 array, with the storage
capacity of only one drive dedicated to store the parity
information. Therefore, RAID 5 arrays provide greater storage
efficiency than RAID 1 arrays. However, this efficiency must be
balanced against a corresponding loss in performance.
The parity data for each stripe of a
RAID 5 array is the XOR of
all the data in that stripe, across all the drives in the array.
When the data in a stripe is changed, the parity information is also
updated. There are two ways to accomplish this:
The first method is based on accessing all of the data in the
modified stripe and regenerating parity from that data. For a
write that changes all the data in a stripe, parity can be
generated without having to read from the disk, because the data
for the entire stripe will be in the cache. This is known as
full-stripe write. If only some of the data in a stripe is to
change, the missing data (the data the host does not write) must
be read from the disks to create the new parity. This is known as
partial-stripe write. The efficiency of this method for a
particular write operation depends on the number of drives in the
RAID 5 array and what portion of the complete stripe is
written.The second method of updating parity is to determine which
data bits were changed by the write operation and then change only
the corresponding parity bits. This is done by first reading the
old data which is to be overwritten. This data is then XORed with
the new data that is to be written. The result is a bit mask which
has a 1 in the position of every bit which has changed. This bit
mask is then XORed with the old parity information from the array.
This results in the corresponding bits being changed in the parity
information. The new updated parity is then written back to the
array. This results in two reads, two writes and two XOR
operations. This is known as read-modify-write.
The cost of storing parity, rather than redundant data as in
RAID 1, is the extra time required for the write operations to regenerate
the parity information. This additional time results in slower write
performance for RAID 5 arrays over
RAID 1. Because Adaptec RAID
controllers generate XOR in hardware, the negative effect of parity
generation is primarily from the additional disk I/O required to
read the missing information and write the new parity. Adaptec RAID
controllers can generate parity using either the full- or
partial-stripe write algorithm or the read-modify-write algorithm.
The parity updated method chosen for any given write operation is
determined by calculating the number of I/O operations needed for
each type and choosing the one with the smallest result. To increase
the number of full stripe writes, the cache is used to combine small
write operations into larger blocks of data. |
| |
|
Handling I/O Errors
|
|
Adaptec
RAID controllers maintain two
lists for each RAID 5 array: a Bad Parity List, and a Bad Data List.
These lists contain the physical block number of any parity or data
block that could not be successfully written during normal write,
rebuild or dynamic array expansion operations. These lists alert the
controller that the data or parity in these blocks is not valid. If
the controller subsequently needs data from a listed block and
cannot recreate the data from existing redundant data, it returns an
error condition to the host.
Blocks are removed from the Bad Parity List or the Bad Data List
if the controller successfully writes to them on a subsequent
attempt. |
| |
|
Degraded Mode
|
|
When a drive fails in a
RAID 0 array, the
entire array fails. In a RAID 1 array, a failed drive reduces read
performance by 50%, as data can only be read from the remaining
drive. Write performance is increased slightly because only one
drive is accessed. A RAID array operating with a failed drive is
said to be in degraded mode.
RAID 5 arrays synthesize the requested data by reading and XORing
the corresponding data stripes from the remaining drives in the
array. For RAID 5, the magnitude of the performance impact in
degraded mode depends on the number of drives in the array. An array
with a large number of drives will experience more performance
degradation than an array with small number of drives. |
| |
|
Rebuilding a Failed Hard
Drive
|
|
A failed drive can be replaced in a
RAID
1 or RAID 5 array by physically removing the drive and replacing it
or by a designated Hot Spare. Adaptec RAID controllers will rebuild
the data for the failed drive onto the new drive or Hot Spare. This
rebuild operation occurs online while normal host reads and writes
are being processed by the array.
RAID 1 arrays are rebuilt relatively quickly, because the data is
simply copied from the duplicate (mirrored) drive to the replacement
drive. For RAID 5 arrays, the data for the replacement drive must be
synthesized by reading and XORing the corresponding stripes from the
remaining drives in the array. RAID 5 arrays that contain a large
number of drives will require more time for a rebuild than a small
array. |
|
|
|